E135
E135 is the first micro gas turbine designed and developed by ENN Power independently. The development of this product has fully considered domestic existing material and equipment levels with a mature structure of gearbox and conventional generator. The core machine components have been 100% localized.
Parameters of E135 Micro Gas Turbine
Thermal performance data |
---|
Simple cycle gas turbine and generator set | |
Rated |
128 kW |
Rated power efficiency |
13.9 % |
Exhaust temperature |
604 ℃ |
Exhaust flow rate |
1.17 kg/s |
Natural gas consumption | 98 Nm³/h |
Recuperated cycle gas turbine and generator set | |
Rated |
116 kW |
Rated power efficiency | 22.1 % |
Exhaust temperature | 308 ℃ |
Exhaust flow rateBoundary Dimensions | 1.14 kg/ s |
Natural gas consumption
|
53 Nm³/h |
Environmental performance data |
---|
NOx* | ≤25 ppm or 50 mg/m³ |
Noise |
≤85 dB(A) |
Dimension parameters |
---|
Simple cycle gas turbine and generator set | |
Boundary Dimensions |
3200x2202x3460 mm |
Weight | 7.4 t |
Recuperatede cycle gas turbine and generator set | |
Boundary Dimensions | 5536x2202x3460 mm |
Weight | 8.1 t |
CCHP data |
---|
Simple cycle gas turbine and generator set | |
Cooling/heating power |
863/552 kW |
Cooling/heating area |
9600-21600 ㎡ |
Recuperated cycle gas turbine and generator set | |
Cooling/heating power | 178/182 kW |
Cooling/heating area | 2000-4400㎡ |
Cogenerated steam output of simple cycle gas turbine and generator set 0.8 t / h. |
---|
E160
The E160F series unit is a breakthrough product of ENN Power's technology. The whole structure and main components have been redesigned. Both the core machine and the high-speed motor adopt air bearings with minimal mechanical loss. It has the best performance and does not require a lubrication system. It represents the most advanced technology in the field of micro-gas turbines in the world.
Parameter of E160F Micro Gas Turbine and Generator Set
Thermal performance data |
---|
Simple cycle gas turbine and generator set | |
Rated output power | 160 kW |
Rated power efficiency | 18 % |
Exhaust temperature | 603 ℃ |
Exhaust flow rate | 1.1 kg/s |
Natural gas consumption | 94 Nm³/h |
Recuperated cycle gas turbine and generator set | |
Rated output power | 136 kW |
Rated power efficiency | 29 % |
Exhaust temperature | 290 ℃ |
Exhaust flow rate | 1.09 kg/s |
Natural gas consumption | 50 Nm³/h |
Environmental performance data |
---|
NOx* | ≤25 ppm or 50 mg/m³ |
Noise level | < 70 dB(A) |
Dimension parameters |
---|
Simple cycle gas turbine and generator set | |
Boundary Dimensions | 2500x1500x2000 mm |
Weight | 3t |
Recuperated cycle gas turbine and generator set | |
Boundary Dimensions | 4500x1500x2000 mm |
Weight | 4t |
CCHP data |
---|
Simple cycle gas turbine and generator set | |
Cooling/heating power | 807/518 kW |
Cooling/heating area | 9000-20200 ㎡ |
Recuperated cycle gas turbine and generator set | |
Cooling/heating power | 191/154 kW |
Cooling/heating area | 2100-4800 ㎡ |
Cogenerated steam output of simple cycle gas turbine and generator set 0.8 t / h. |
---|