E2100
E2100
E2100 gas turbine & generator parameters
Thermal performance data |
---|
Simple cycle gas turbine and generator set | |
Rated output power | 1966 kW |
Rated power efficiency | 20.7 % |
Exhaust temperature | 578 ℃ |
Exhaust flow rate | 11.9 kg/s |
Natural gas consumption | 1005 Nm³/h |
Recuperated cycle gas turbine and generator set |
Rated output power | 1721 kW |
Rated power efficiency | 30.4 % |
Exhaust temperature | 320 ℃ |
Exhaust flow rate | 11.6 kg/s |
Natural gas consumption | 599 Nm³/h |
Thermal performance data |
---|
NOx* | ≤25 ppm or 50mg/m³ |
Noise level | TBD |
Dimension parameters |
---|
Recuperated cycle gas turbine and generator set | |
Boundary Dimensions | 8000x2420x3331 (this height does not include the air intake system, with the air intake system the total height of the machine is 6652mm) |
Weight | 30t |
simple cycle gas turbine and generator set | |
Boundary Dimensions | 8000x2420x3331 (this height does not include the air intake system, with the air intake system the total height of the machine is 6652mm) |
Weight | 40t |
CCHP data |
---|
Smiple cycle gas turbine and generator set | |
Cooling/heating power | 8252/5296 kW |
Cooling/heating area | 91800-206600 ㎡ |
Recuperated cycle gas turbine and generator set | |
Cooling/heating power | 1969/1999 kW |
Cooling/heating area | 21900-49200 ㎡ |
Cogenerated steam output of simple cycle gas turbine and generator set 7.7 T/h. |
---|